Description
This is a vandal resistant proximity card and keypad access control unit suitable for external applications. The unit accepts up to 500 users and provides entry via the use of proximity cards and/or pin codes.
* Technical Specification:
** Operating Voltage:
1) 12VDC From a Regulated Power Supply Input current:
2) Standby: 40mA Not including attached devices
3) Max: 130mA Not including attached devices
** Outputs:
1) Lock Strike Relay From C, 5A
2) Auxiliary Relay From C, 5A
3) LockStrike Control Output Collector Open Output (25mA)
4) Auxiliary Control Output Collector Open Output (25mA)
** Inputs:
1) REX: N.O.,Dry Contact
2) Auxiliary Input (In/Monitor): N.C.,Dry Contact in
Monitor Mode: N.O.Dry Contact Input Mode
** Built-in Proximity reader
1) Read Range: 65mm
2) Modulation: ASK at 125 kHz
3) Compatible Cards: ALL 26-Bit EM Cards
** Mechanical Characteristics
1) Dimentions: 120L*76W*27Hmm
2) Weight: 450g
Range also depends on electrical environment and proximity to metal.
* Features:
1) Built-in Proximity Card Reader (125KHZ ASK Modulation)
2) Built-in Keypad for PIN Code entry
3) Auxiliary Input & Auxiliary Output
4) Eight Auxiliary Modes including: Door Ajar; Forced Door; Shunt; Door Monitor; Normal / Secure
5) Internal Buzzer
6) Two Status/Programming Interface LED'S
7) Two Modes of Operation: Normal Mode; Secure Mode
8) Three User Levers: Normal User; Secure User; Master User
9) Four Open door mode: 4 digit Pin Code; 4 digit Pin Code & EM Card; 4 digit Pin Code & 1.4 digit Pin Code; EM Card & EM Card
10) Code search Feature that helps make maintaining user codes easier.
11) Built-in Case and Back Tamper Bell, Chime, Siren, Battery Backup, Tamper Output features available with IBA Power Supplies.
12) Programmable Siren Time.
13) Programmable Lock Strike Release Time.
View AllClose
* Technical Specification:
** Operating Voltage:
1) 12VDC From a Regulated Power Supply Input current:
2) Standby: 40mA Not including attached devices
3) Max: 130mA Not including attached devices
** Outputs:
1) Lock Strike Relay From C, 5A
2) Auxiliary Relay From C, 5A
3) LockStrike Control Output Collector Open Output (25mA)
4) Auxiliary Control Output Collector Open Output (25mA)
** Inputs:
1) REX: N.O.,Dry Contact
2) Auxiliary Input (In/Monitor): N.C.,Dry Contact in
Monitor Mode: N.O.Dry Contact Input Mode
** Built-in Proximity reader
1) Read Range: 65mm
2) Modulation: ASK at 125 kHz
3) Compatible Cards: ALL 26-Bit EM Cards
** Mechanical Characteristics
1) Dimentions: 120L*76W*27Hmm
2) Weight: 450g
Range also depends on electrical environment and proximity to metal.
* Features:
1) Built-in Proximity Card Reader (125KHZ ASK Modulation)
2) Built-in Keypad for PIN Code entry
3) Auxiliary Input & Auxiliary Output
4) Eight Auxiliary Modes including: Door Ajar; Forced Door; Shunt; Door Monitor; Normal / Secure
5) Internal Buzzer
6) Two Status/Programming Interface LED'S
7) Two Modes of Operation: Normal Mode; Secure Mode
8) Three User Levers: Normal User; Secure User; Master User
9) Four Open door mode: 4 digit Pin Code; 4 digit Pin Code & EM Card; 4 digit Pin Code & 1.4 digit Pin Code; EM Card & EM Card
10) Code search Feature that helps make maintaining user codes easier.
11) Built-in Case and Back Tamper Bell, Chime, Siren, Battery Backup, Tamper Output features available with IBA Power Supplies.
12) Programmable Siren Time.
13) Programmable Lock Strike Release Time.